What Is an Electrical Installation Condition Report (EICR) and Why Is It Important?

An Electrical Installation Condition Report (EICR) is a professional and official inspection of a building's fixed wiring, consumer unit, and accessories to verify that the installation is safe for further use. If one lives in the UK, it is advised to carry out a domestic inspection every ten years, while a private landlord should obtain a landlord electrical certificate or a landlord electrical safety certificate every five years or on changing tenancy, whichever occurs first.

An EICR inspection can be compared to an MOT test but for the electricity of the building. One cannot see the copper wiring hidden behind plasterboard or detect a faulty earth connection or an overheated terminal in a fuse box. The biggest problem is the silent deterioration of the fixed wiring. The issue causes 76% of accidental fires across the whole country.

Important Point: Safety in the electrical industry is not equal to operating electrical devices safely. With the help of regular EICR testing, whatever is hidden can be revealed before the problems have time to turn into electric fires, legal consequences, or invalidation of insurance agreements.

For example - Kevin is a very responsible owner living in the region of Midlands where she leases out her building comprising several flats. Kevin has managed the building for years and has never received any complaints. But there was one time when Kevin asked for an EICR check to be done before a lease renewal contract. Believe it or not, the lineman came to know that the electric shower circuit had been installed by the old team without having earthing control and dampness in the earthing system of the basement.

In case there was any problem with the electric shower circuit, the metal casing would have been live without causing a switch trip in the consumer unit. Luckily enough, as Kevin had thought it wise to have the test done, he had saved himself from an electric shock, a £30,000 fine, and an event whereby his buildings insurance would have been declared void. The previously presented sample indicates the necessity of remembering that electrical systems change for the worse without making any sign until they stop functioning properly.

It is common for people to inquire about the cost of their examination. It is difficult to give an estimate here because the cost does not depend on the amount, but on the size and age of the building. Most experts advise using the number of circuits in the consumer unit and the overall plan of the building when calculating the price.

Several factors should be considered when you estimate the cost:

  • Number of circuits: Testing a small one-bedroom flat with six circuits is quicker than testing a large four-bedroom home or a commercial property with twenty or more.
  • Age and accessibility of the property: Older buildings will likely have older and sometimes even dangerous wiring or fuse board problems and junction box access issues.
  • Location and parking facilities: Urban areas with congestion charge or parking issues might slightly affect call-out charges.

Beware of very low quotes offered on the Internet. Quick visual check of the system without proper live and dead circuit testing might result in missing some serious defects, which will lead to future financial losses for you. A clear and well-considered circuit quotation is always the right way to go.

First things first - An EICR inspection can be conducted only by a licensed electrician who is a member of one of the government-approved programs such as NICEIC or NAPIT.

The certified engineer inspects the following during the visit:

  • Consumer unit (fuse box): Check overheating, burns, safety of connections and RCDs that automatically switch off electricity in case of any fault.
  • Fixed wiring and earthing: Bonding of gas and water pipes and earthing.
  • Switch sockets and lights: Check their usability and stability.
  • Testing of dead live circuits: Instruments will be used to measure the insulation of earthed circuits and circuit continuity.

This inspection will cause a temporary power outage, hence informing the occupants ahead of the short inconvenience.

Once EICR testing is complete, you receive an official electrical safety certificate detailing any defects using strict industry classification codes:

Observation Code What It Means Required Action & Report Outcome
C1 (Danger Present) Instant hazard of injury or fire. The technologist makes the circuit safe before his departure. Vital, instant corrective work required. Outcome: Unsatisfactory.
C2 (Potentially Dangerous) Not currently a threat but could be dangerous if there is a problem in the future. Urgent remedial action needed (within 28 days for landlords). Outcome: Unsatisfactory.
FI (Further Investigation) A discrepancy discovered suggesting further investigation needed to assure safety. Additional tests required without delay. Outcome: Unsatisfactory.
C3 (Improvement Recommended) Fails to conform to the latest norms, but not at present threatening safety. Advised for use of best practices, especially during enhancements. Outcome: Satisfactory.

The report will be considered unsatisfactory in case the certificate bears any of C1, C2, or FI codes. However, when the faults have been sorted out by an electrician, a piece of written documentation (Minor Electrical Installation Works Certificate) will be issued, which will accompany the report.

The frequency of EICR certificates depends on the different categories of the property. The usage of every property is different and hence the requirement of EICR is different

  • Private lease properties: The Electricity Safety Standards in the Private Rental Sector (England) Regulations stipulate that landlords ensure inspection reports are conducted every 5 years. Furthermore, it specifies that the certificates must be provided to the current tenants within 28 days of the inspection and to the local authority upon request within 7 days.
  • Residential Units: Although it is not legally mandated, it is generally recommended that an EICR is conducted every 10 years, or before exchanging contracts when buying a property. (IET Guidance Note 3)
  • Commercial Buildings: All Office, retail and hospitality establishments must be inspected every 5 years while Industrial Buildings every 3 years, and high-risk sites such as Swimming pools and Construction sites every 3 months to a year. (Electricity at Work Regulations 1989)
  • Holiday Destinations: Due to high turnover, a maximum of 5 years is set.

1- Please plan your inspection ahead

2- Make sure you book a certified professional only (NICEIC or NAPIT)

3- Do not take their observations lightly

4- Keep your paperwork ready

5- Make sure there is clear access to the fuse box

Electrical safety is very important. Even a small negligence can lead to much loss of life and money. It is of paramount importance to regularly conduct EICR inspections.

The whole process will save you from government penalties from default. Having regular inspections as part of your EICR will help to identify any underlying issues with your electrical system. Thus, eliminating the potential risks of fire. As a homeowner, landlord or business owner investing in ensuring your electrical systems are safe can help you to avoid any serious issues in the future.

Make no compromises with your safety and book a consultation with Man Electrotechnical today. They will provide an NICEIC or NAPIT certified professional, who will make sure the entire process is transparent and smooth.